Tyco Fire Protection Products showcased its experience in water mist suppression options on the International Water Mist Association (IWMA) Conference in Istanbul. Dr Tim Nichols, Sales Director Water Mist EMEA, gave a presentation entitled ‘Fire Protection of Compact Archive Storage utilizing Water Mist’, where he mentioned how the extinguishant is well suited to the protection of irreplaceable works and artefacts in extremely useful buildings.
เกจวัดแรงดันน้ำ on a fire check protocol that was formulated to verify the efficiency and use of Tyco’s personal water mist answer, AquaMist, in an historic constructing, residence to precious archive storage. The National Fire Protection Association (NFPA) 750 commonplace requires that, when using a water mist suppression system, fireplace testing is undertaken pertinent to the danger. However, of the printed fire check protocols listed in NFPA 750, none particulars the necessities for archives that include curler (compact) racking. Many of the racks within the focused constructing are of the ‘roller’ type, which restrict the amount of space for constructing services, together with these for extinguishing system pipework.
Together with the venture stakeholders, Tyco devised the protocol to include test rig and format, check sort, hearth load, information acquisition (for instance, sensors and imaging), hardware required (such as pumps, nozzles, pipe, tank, generator), and health and safety procedures (for occasion, the hearth brigade). The associated efficiency based fireplace tests have been then designed to replicate the range of utility parameters associated with archive storage.
While ignition sources at the original web site were recognized to be minimal, and the primary hearth supply confirmed as arson, the multi-level constructing poses numerous challenges that needed to be considered when formulating the hearth check protocol to ensure effective protection. Low ceilings and numerous obstructions, corresponding to lighting, ducts and pillars, contribute in the path of the confined setting of the archive storage basement level. Items are saved in a combination of open racks and compact racks, which offer less than a 150mm hole between themselves and the ceiling, and there could be limited on-site water storage. Pre-test risk analysis additionally highlighted restricted entry and exits beneath and above ground, so it’s essential for cupboard space to be maximised and secure egress provided in case of the event of a fire. In addition, the highly priceless nature of the storage contents meant that the selected fireplace suppression solution had to ensure minimal harm to these historic objects.
To achieve validation, the checks had to meet varied aims. These comprised fast management of the hearth inside a prescribed area (in this case, outlined as within a block of racks); control of temperature; attenuation of radiation; and minimisation of collateral damage through water clean-up. They also had to keep in mind various parameters, including the desired excessive strain mist system; a 30 minute run time; and an annual measurable achievement objective (AMAO) defined in accordance with a formula based mostly on the amount of nozzles activating throughout testing.
The hearth checks, carried out for each open and curler racks with minimum storage gaps, have been undertaken in a customised test rig, designed, built and fitted to duplicate the exact specification, racking preparations and storage materials of the location. Considered a excessive load, the gas supplies have been similar to that found in archive storage, including paper, books, micro-film and CD instances.
Success was defined by pass or fail criteria and determined by detailed quantitative measurements on system configuration, hydraulic analysis, discharge strain, discharge sequence, hearth spread, temperature, fireplace injury and water consumption. In each exams, Tyco’s AquaMist system operated successfully and was observed to suppress and management the fireplace efficiently. The challenge group was impressed by the dearth of fire and smoke harm to the supplies and construction and the product has since been put in in the building in query.
“The IWMA convention is a unbelievable opportunity to highlight the benefits of water mist as a fireplace suppression solution, in addition to demonstrate its versatility in a variety of functions,” feedback Dr Tim Nichols. “Identifying a gap out there and taking the opportunity to formulate a hearth test protocol for archive storage enabled us to validate the professional capabilities of our AquaMist system and facilitate protection of a customer’s extremely priceless belongings.”
For more info, go to www.tfppemea.com
Share

Leave a Reply