The leading ignition protection type is critical for the electrical connection of a pressure sensor with explosion protection. It does not necessarily must be the one with the stricter requirements. This applies, for example, for the UHP pressure transducers of the WU series from WIKA. They have been designed for use in semiconductor production.
Explosion protection can be an indispensable safety precaution there. For the reason that the substances necessary for manufacturing include highly flammable gases. Consequently, you will find a threat of an explosive atmosphere forming.
Explosion protection concept
UHP pressure transducers for such processes must be made with the corresponding safety. In addition to their small design and specific process connections, the models WUC-1x and WU-2x have a comprehensive explosion protection concept. The marking of the instruments provides information on this:
II 3G Ex ec ic IIC T6/T5/T4 Gc X
The abbreviations listed inside them mean, in greater detail:
II 3G:
Equipment group 2 (every area except mining), can be utilized in zone 2 (rare and short-term Ex atmosphere).
Ex ec ic:
Ignition protection types ?ec? (increased safety) and ?ic? (intrinsically safe; zone 2).
?Ex ec? has replaced the ignition protection type ?Ex nA? (non-sparking) since the start of 2022. However, this will not affect the Ex idea of the instruments.
IIC:
Explosion group (here: gases, resistive ignition energy of 40 �J, ideal for hydrogen/acetylene).
T6/T5/T4:
Temperature classes. T6 because the highest requirement means a maximum permissible surface temperature in the Ex environment < 85 �C (max. surface temperature of the WUC-1x and WU-2x: 40 �C).
Gc:
?Equipment Protection Level? (EPL) for zone 2 per IEC 60079-0
X:
Specific requirements which are listed in the operating instructions (for instance, the suitable mating connector).
?ec? is the leading ignition protection type
It is noticeable that the marking contains two ignition protection types. However, only 1 is pertinent for the electrical connection: the leading ignition protection type. Regarding the pressure transducers from the WU series, it is the Ex ec (Ex nA up to 2022) mentioned first rather than the stricter Ex ic. This may also be seen in the connection values in the info sheet and operating instructions. Only the specification of the maximum supply voltage UN = 30 V, that is also stated in the IECEx certificate, is pertinent here.
What does Monetize ?Ex ic? are a symbol of? It only pertains to the potentiometer of the transducer. The resistive component has an intrinsically safe circuit and will therefore be adjusted to correct zero drift during operation. Within their overall form, the WU models usually do not require an intrinsically safe circuit. However, they must never be disconnected from the circuit during operation or when an Ex atmosphere exists.
Note
More info on the WUC-1x and WU-2x UHP pressure transducers and about hydrogen can be found on the WIKA website. For those who have any questions, your contact will gladly help you.